FX2N-4AD Mitsubishi PLC
| Analog output | Analog output range | Voltage output | DC-10V to + 10V (External load resistance 2kΩ to 1MΩ) |
| Current output | DC 0mA to + 20mA (External load resistance 500Ω or less) | ||
| Number of output channels | 4 channels | ||
| Output characteristics | The output mode (voltage / current output) can be set for each channel. | ||
| Digital input | Voltage output | 11bit binary + sign 1bit | |
| Current output | 10bit binary (unsigned) | ||
| resolution | Voltage output | 5mV (10V x 1/2000) | |
| Current output | 20μA (20mA × 1/1000) | ||
| Overall accuracy | Voltage output | ± 1% (± 0.2V) for full scale 20V (Excluding load fluctuation) |
|
| Current output | ± 1% (± 0.2 mA) for full scale 20 mA | ||
| D / A conversion time | 2.1ms / 4 channels (regardless of the number of channels used) | ||
| Insulation method | The analog output section and sequencer are isolated by a photocoupler The analog output section and power supply are isolated by a DC / DC converter Each channel is not isolated |
||
| Number of occupied I / O points | 8 points (can be counted by either input or output) | ||
| Applicable sequencer | FX2N, FX3U, FX2NC, FX3UC <Connecting to the connector type sequencer> FX2NC-CNV-IF is required to connect to FX2NC. FX2NC-CNV-IF or FX3UC-1PS-5V is required for connection to FX3UC. |
||
| mass | 0.3kg | ||
| Power supply specifications | |||
| Power supply | 5V 30mA (Internal power supply from PLC) DC24V ± 10% 200mA (External power supply) |
||










Reviews
There are no reviews yet.